Sensorsoft ST6105C Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Redes Sensorsoft ST6105C. Sensorsoft ST6105C User manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 89
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Sensorsoft
Sensorsoft
Alert
The Standalone Network Appliance for Environmental Monitoring
User Manual
For models SSA7001, SSA7004 and SSA7008
With Image Build Number 13 or Higher
Manual P/N 071-0084 Rev 21 January 2, 2015
Copyright © 2004-2015 Sensorsoft Corporation, All rights reserved.
Sensorsoft, Remote Watchman and Alert are trademarks of Sensorsoft Corporation.
Vista de página 0
1 2 3 4 5 6 ... 88 89

Resumo do Conteúdo

Página 1 - Sensorsoft 

Sensorsoft  Sensorsoft Alert™ The Standalone Network Appliance for Environmental Monitoring User Manual For models SSA7001, SSA7

Página 2

Sensorsoft Alert User Manual Software specifications and features SSA7001 Max Number of Sensors or Devices  1 Supported Protocols  HTTP  FT

Página 3

Sensorsoft Alert User Manual SSA7004 and SSA7008 Max Number of Sensors or Devices  4 for SSA7004  8 for SSA7008 Supported Protocols  HTTP 

Página 4 - Table of Contents

Sensorsoft Alert User Manual Hardware specifications SSA7001 CPU 50 MHz MPC855T (PowerPC Dual-CPU) Memory 32 MB RAM / 4 MB Flash Interfaces 1 Etherne

Página 5

Sensorsoft Alert User Manual Safety Instructions Read the following safety guideline to protect yourself and your Sensorsoft Alert Appliance.  DANG

Página 6

Sensorsoft Alert User Manual FCC & DOC Notice FCC Warning Statement This equipment generates, uses, and can radiate radio-frequency energy, and i

Página 7 - About This Manual

Sensorsoft Alert User Manual Alert Quick Start This section will show you how to bring your Alert appliance up on the network. There are two differe

Página 8 - Glossary of Acronyms

Sensorsoft Alert User Manual Connecting to the Alert serial port console The Alert console port (DB-9M connector) is an RS232 serial interface that c

Página 9 - Overview

Sensorsoft Alert User Manual Models SSA7004 and SSA7008 To connect to your SSA7004 or SSA7008 appliance through its console port, you first need the

Página 10 - SSA7001

Sensorsoft Alert User Manual a. When prompted with the question “Set to defaults ? (y/n)”, type N and press the Enter key. b. You can now configure

Página 11 - SSA7004 and SSA7008

Sensorsoft Alert User Manual 9M port. If the Sensorsoft device is the J-Type (i.e. ST6105J, ST6154J, SM6204J, SS6610J, SP6400J, SS6402J, SS6201J), th

Página 13 - Replacing the Battery

Sensorsoft Alert User Manual Alert web interface Accounts and passwords The Sensorsoft Alert web interface uses two accounts for access rights. The f

Página 14 - FCC & DOC Notice

Sensorsoft Alert User Manual Changing web login passwords: 1. Login to the Alert web interface as admin. 2. Click on the Change Passwords hyperlink

Página 15 - Alert Quick Start

Sensorsoft Alert User Manual 6. After your Alert appliance has rebooted, you will be able to login to its web interface with username: admin and pas

Página 16

Sensorsoft Alert User Manual Shutting down or rebooting the Alert Appliance IMPORTANT - It is highly recommended that you use the web interface to s

Página 17 - Models SSA7004 and SSA7008

Sensorsoft Alert User Manual Figure 5: Configuring port settings 4. In the Data Log Interval field, enter the data logging interval in minutes. T

Página 18 - Model SSA7001

Sensorsoft Alert User Manual The View Monitor List Page To access the View Monitor List page, click on the hyperlink View Monitor List on the left si

Página 19

Sensorsoft Alert User Manual Monitor List Auto-Refresh Interval The Monitor List page (see Figure 6) auto-refreshes at a regular interval to continuo

Página 20 - Alert web interface

Sensorsoft Alert User Manual Figure 7: Device Configuration Page 3. Figure 7 above shows the Device Configuration page for a SS6610J Sensorsoft Te

Página 21

Sensorsoft Alert User Manual entries for each variable; the SSA7008 model can store the most recent 200 log entries for each variable. You can also

Página 22 - Setting date and time

Sensorsoft Alert User Manual Figure 8: Enabling logging of variable readings 5. Click on the Save Changes button. Logging Data Sensorsoft Alert

Página 23

Warning: This manual should only be used for Sensorsoft Alert running image build 13 or higher. To upgrade your appliance’s image to the late

Página 24 - Support

Sensorsoft Alert User Manual _Port01_Var1.log _Port08_Var4.log Graphing data files The data logged by Sensorsoft Alert can be graphed using the inte

Página 25 - The View Monitor List Page

Sensorsoft Alert User Manual  allow the Alert appliance read/write privileges to this directory The following example shows how to modify the /etc

Página 26

Sensorsoft Alert User Manual Setting up Alerts Your Alert appliance has the ability to alert you when a variable reading is in a warning or critical

Página 27

Sensorsoft Alert User Manual Figure 8b: Setting alerting limits for a scalar variable If the variable is Boolean, you can be alerted when its value

Página 28

Sensorsoft Alert User Manual Figure 10: SMTP Settings on the Administration Page You must enter at least one valid SMTP server address to be used fo

Página 29 - Logging Data

Sensorsoft Alert User Manual Figure 11: Configuring Email Alerts for a Scalar Variable Notice that for a scalar variable, you can configure email a

Página 30 - Logging Data on a NFS Server

Sensorsoft Alert User Manual 6. In each Message field, specify the email message to be sent for the corresponding alert condition. You may want to

Página 31

Sensorsoft Alert User Manual Figure 12: Paging Settings on the Administration Page 3. Select the port where the modem connected. 4. Select the cor

Página 32 - Setting up Alerts

Sensorsoft Alert User Manual Figure 14: Configuring pager alerts for a scalar variable Notice that for a scalar variable, you can configure pager al

Página 33 - Setting up Email Alerts

Sensorsoft Alert User Manual Setting up SNMP Trap Alerts SNMP trap alerts are suitable for users who need to manage their Alert appliance through SN

Página 34

Table of Contents About This Manual...

Página 35

Sensorsoft Alert User Manual 2. From the Device Configuration page, click on the Setup SNMP Traps for this variable hyperlink for the device variable

Página 36 - Setting up Pager Alerts

Sensorsoft Alert User Manual Setting up command line alert to control a Sensorsoft Relay A Sensorsoft Relay can be controlled to turn ON or OFF when

Página 37

Sensorsoft Alert User Manual Figure 17: Configuring Command Line Alerts for a Scalar Variable In the example shown in Figure 17, above, the Alert

Página 38

Sensorsoft Alert User Manual In the command lines above, ttyS4 is the name used to access serial port 4. The relay can be connected to any serial po

Página 39 - Setting up SNMP Trap Alerts

Sensorsoft Alert User Manual Upgrading the firmware on your Alert Appliance Sensorsoft recommends that you keep your Alert appliance’s firmware up-to

Página 40

Sensorsoft Alert User Manual Root User The root username is used to login to Alert’s Linux shell. The default root password is sensorsoft. It is rec

Página 41

Sensorsoft Alert User Manual  The P/N C2013 cable that came with your Alert appliance. This is a blue RJ-45 straight-through cable. 1. If the Aler

Página 42

Sensorsoft Alert User Manual Backup files on Alert appliance to a remote host There are several circumstances where you may want to backup files on

Página 43

Sensorsoft Alert User Manual Restore known good script backup file to Alert appliance from a remote host If you are experiencing problems accessing

Página 44

Sensorsoft Alert User Manual SNMP Interface Sensorsoft Alert SNMP Agent Specifications SNMP Version supported 1 Commappliancey Names Multiple commap

Página 45 - Root User

Setting up Alerting Limits for Device Variables...32 Setting up Email Alerts ...

Página 46

Sensorsoft Alert User Manual Sensorsoft Alert Indexed MIB Usage Readings from device variables are accessed through the ssVarReading MIB object. Alth

Página 47 - # saveconf

Sensorsoft Alert User Manual To enable a specific alert action for a particular alert state, the corresponding ssXXXXXXEnable MIB object must be set

Página 48

Sensorsoft Alert User Manual To enable a specific alert action for a particular alert state, the corresponding ssXXXXXXEnable MIB object must be set

Página 49 - SNMP Interface

Sensorsoft Alert User Manual by setting the ssTrapOnBooleanCriticalEnable to 1. By default, traps will be repeatedly sent at 5 minute intervals as

Página 50

Sensorsoft Alert User Manual This is done by setting the ssDeviceIndex MIB object to the index of the serial port where the monitored device is conne

Página 51

Sensorsoft Alert User Manual This is done by setting the ssDeviceIndex MIB object to the index of the serial port where the device is connected. For

Página 52

Sensorsoft Alert User Manual Type The object type describes the variable type of the object. Typical variable types include IPAddress, Integer, and

Página 53

Sensorsoft Alert User Manual OID .1.3.6.1.4.1.15848.1.4.0 ssTrapDestination1 DESCRIPTION: The destination IP address for sending traps to the firs

Página 54

Sensorsoft Alert User Manual Non-volatile ssDeviceIndex DESCRIPTION: The user-defined index to select a particular device. The device on the first p

Página 55

Sensorsoft Alert User Manual ssNumVariables DESCRIPTION: The total number of variables supported by the currently indexed device. TYPE: Integer ACCES

Página 56

Returns ...79 Appendix

Página 57

Sensorsoft Alert User Manual ACCESS: Read Only OID .1.3.6.1.4.1.15848.1.20.0 ssVarStatus DESCRIPTION: The status of the currently indexed variabl

Página 58

Sensorsoft Alert User Manual ACCESS: Read-Write OID .1.3.6.1.4.1.15848.1.25.0 Non-volatile ssScalarWarningLowLimit DESCRIPTION: If the currently i

Página 59

Sensorsoft Alert User Manual TYPE: String ACCESS: Read only OID .1.3.6.1.4.1.15848.1.30.0 ssBooleanCriticalState DESCRIPTION: The user-definable s

Página 60

Sensorsoft Alert User Manual ssTrapOnScalarWarningInterval DESCRIPTION: The time interval in minutes between traps when the agent detects that the c

Página 61

Sensorsoft Alert User Manual Critical Low Limit status. The subject line can also contain the dollar variables: $L, $U, $R, and $T. The dollar varia

Página 62

Sensorsoft Alert User Manual Non-volatile ssEmailOnScalarCriticalInterval DESCRIPTION: The time interval in minutes between emails when the current

Página 63

Sensorsoft Alert User Manual TYPE: String ACCESS: Read/Write OID .1.3.6.1.4.1.15848.1.46.0 Non-volatile ssEmailOnScalarWarningEnable DESCRIPTION:

Página 64

Sensorsoft Alert User Manual will be expanded to the currently indexed device’s location. The dollar variable $U, will be expanded to the location o

Página 65

Sensorsoft Alert User Manual currently indexed device’s location. The dollar variable $U, will be expanded to the location of the Alert appliance.

Página 66

Sensorsoft Alert User Manual ssCommandOnScalarCriticalHigh DESCRIPTION: This is the command-line string that will be executed by the shell when the c

Página 67

Sensorsoft Alert User Manual 7About This Manual This document contains information about the initial setup, routine configuration, usage and troubl

Página 68

Sensorsoft Alert User Manual TYPE: Integer ACCESS: Read/Write OID .1.3.6.1.4.1.15848.1.62.0 Non-volatile ssCommandOnScalarWarningHighInterval DE

Página 69

Sensorsoft Alert User Manual ssCommandOnScalarCriticalLow DESCRIPTION: This is the command-line string that will be executed by the shell when the c

Página 70

Sensorsoft Alert User Manual ssCommandOnBooleanCriticalEnable DESCRIPTION: A zero value disables this command line alert. A value of one enables this

Página 71

Sensorsoft Alert User Manual Security Considerations IMPORTANT - If you are planning to expose your Alert appliance to the Internet, Sensorsoft recom

Página 72

Sensorsoft Alert User Manual Trouble Shooting General Problems Cannot access the web interface anymore If you cannot access the Alert appliance web

Página 73 - Security Considerations

Sensorsoft Alert User Manual Sensorsoft device readings have erroneous values This can occur if your Sensorsoft device has EEPROM failure or if it ex

Página 74 - Trouble Shooting

Sensorsoft Alert User Manual 2. The monitored device is not properly connected or is damaged. First, make sure the device is properly connected to t

Página 75

Sensorsoft Alert User Manual Paging Problems Please note that the paging feature is not available on the SSA7001 model appliance. If you are using S

Página 76 - Email Problems

Sensorsoft Alert User Manual Timeout, modem did not connect The modem dialed but did not connect to another modem at the destination phone number. Yo

Página 77 - Paging Problems

Sensorsoft Alert User Manual Getting Help Limited Warranty Sensorsoft Corporation warranties this Sensorsoft product to be free from manufacturing de

Página 78

Sensorsoft Alert User Manual Glossary of Acronyms CRC – Cyclic Redundancy Check – an algorithm for finding errors in data packets IANA – Internet Ass

Página 79 - Getting Help

Sensorsoft Alert User Manual Appendix A - Using Dollar Variables in Messages You will notice that the Email Subject Line, Email message line and Page

Página 80 - Messages

Sensorsoft Alert User Manual Appendix B - Controlling the SR6171J Sensorsoft Relay using Command Lines The SR6171J Sensorsoft Relay can be turned on

Página 81

Sensorsoft Alert User Manual Appendix C - Pager Tutorial Sensorsoft Alert supports three methods that can be used to issue alerts to your paging devi

Página 82 - Appendix C - Pager Tutorial

Sensorsoft Alert User Manual SMS Paging Sensorsoft Alert can use the TAP protocol to send SMS messages to your paging device using your computer’s mo

Página 83

Sensorsoft Alert User Manual Appendix D - Modem DIP Switch Settings Modem DIP switch settings required for use with Sensorsoft Alert Paging If you ha

Página 84

Sensorsoft Alert User Manual Appendix E – Alert Serial Port Pin-outs The following table specifies the serial port pin-outs for SSA7001, SSA7004 and

Página 85

Sensorsoft Alert User Manual Appendix F – Using XML Output to Move Data to other Applications Accessing the XML page This section describes how to

Página 86 - Data to other Applications

Sensorsoft Alert User Manual XML data organization This following tree diagram illustrates how data is organized in the XML page: AboutDefaultitem

Página 87 - XML data organization

Sensorsoft Alert User Manual Appendix G – Setting up a Routine Email Notification within the Linux shell The following Linux shell script allows you

Página 88

Sensorsoft Alert User Manual 89-h mailserver sleep 60 # prevents server bind address not available issue /usr/bin/scomd -F /etc/scomd_port1.ini tt

Página 89

Sensorsoft Alert User Manual Overview Sensorsoft Alert is a line of standalone, network-ready appliances that allow you to monitor remote environment

Comentários a estes Manuais

Sem comentários